RECI wiring, SWA armoured cable and Cat6 broadband
Connecting a garden room from your house fuse board using steel-wire armoured (SWA) cable and an independent sub-board is Restricted Electrical Works in Ireland. Only a Safe Electric Registered Electrical Contractor can certify the installation under I.S. 10101, typically adding €1,200 to €2,600. Running a separate 50 mm data duct for external-grade Cat6 ethernet in the same open trench guarantees drop-free video calls.
How power and gigabit internet are safely trenched from your main fuse board to a garden room under Irish I.S. 10101 standards.
Free, no obligation. One local builder prices it, not five.
- €1,200–€2,600SWA supply, sub-board & Cat6
- 450–600 mmarmoured cable trench depth
- 32 A – 40 Atypical dedicated sub-main
- I.S. 10101Safe Electric wiring standard

What a compliant Irish garden room electrical package includes
- Dedicated breaker at the main house board. Feeds a steel-wire armoured (SWA) cable sized for voltage drop over your exact garden length (typically 6 mm² or 10 mm² 3-core SWA).
- Buried conduit with warning tape. Laid 450 mm to 600 mm deep across lawns (600 mm+ under driveways) inside red ESB-style ducting with yellow electrical marker tape above.
- Independent garden room consumer unit. Fitted with an incoming isolator plus RCBO circuit breakers separating sockets, LED lighting, heating and exterior wall lights.
- Safe Electric Completion Certificate. Issued by a Registered Electrical Contractor (REC) after insulation resistance, earth loop impedance and RCD trip testing under I.S. 10101.
Price my garden room
Four quick taps and our Irish price range appears before we ask for a phone number. One local builder rings you, not five.
An insulated garden office, 9 to 12 m², turnkey timber or SIPs: €18,500 to €25,500, built in Ireland.
How the garden room price is calculated
Figures reflect current turnkey Irish rates (€1,800 to €2,700 per m²) for insulated C24 timber, SIPs or light-gauge steel builds with screw-pile or concrete pad foundations, EPDM warm flat roof, double-glazed doors and internal electrics. Armoured SWA cable trenching from your main fuse board, crane lifts over terraced houses, steep ground levelling and foul drainage connections vary by plot and are itemised after an on-site survey. Confirm whether VAT is quoted at 13.5% or 23% before signing.
Hardwired Cat6 ethernet versus Wi-Fi mesh
Hardwired Cat6 in separate duct
- Connection stability
- Full 1 Gbps wired line; zero drop-outs
- Extra cost while trench is open
- €150 to €350 for duct, Cat6 cable & access point
- Interference rule
- Run in a second parallel duct 100 mm+ from SWA power
Wireless mesh / powerline plugs
- Connection stability
- Weakened by foil-faced PIR insulation & rain
- Extra cost while trench is open
- €120 to €280 for outdoor-capable mesh nodes
- Interference rule
- Powerline adapters often struggle across RCBO sub-boards
Related garden room guides
Insulated garden office (10–15 m²)Full-year PIR insulated workspaces wired for Cat6 and quiet winter calls.
Glazing & year-round heatingThermal-break aluminium vs uPVC doors and ceramic heaters vs air-to-air units.
Garden room with WC & kitchenettePlumbing costs, foul drainage options and Irish Class 3 planning caveats.
Garden room prices per m²Complete Irish breakdown by m², structural frame, foundations and VAT.
Class 3 planning rulesS.I. 600/2001 25 m² floor limit, 25 m² lawn left, 3 m/4 m height & Section 5.
Multi-use family room / teenage denWide 20 to 25 m² rooms built with sliding doors and warm acoustic walls.Answers before you commit to a build
Can I plug a garden office into an outdoor 13 A garden socket?
No. An insulated office with heating, lighting, monitors and exterior fixtures requires a dedicated hardwired SWA sub-main certified by a Safe Electric contractor, not an extension lead.
Who digs the trench across the garden?
Clarify this before signing: some builders excavate and backfill the trench as part of groundworks, while others ask the homeowner or electrician to open the trench before cable pull.
Do I need an earth rod at the garden room?
Your Safe Electric contractor verifies your house earthing arrangement (typically TN-C-S in Ireland) and decides whether exported earth or a local TT earth electrode is required under I.S. 10101.
How many double sockets should I plan inside a 15 m² room?
Specify at least 6 to 8 brushed steel or white double sockets (including USB-C points at desk height), plus a fused spur for the wall heater and an external waterproof double socket on the porch.